
REACT Corrosion Control
React Corrosion Control in Hydroprocessing Units
A result of hydroprocessing reactions is the production of hydrogen sulfide and ammonia from contaminants removed from the hydrocarbon streams. As the effluent from the hydroprocess reactor is cooled through subsequent heat exchangers, the gas phase hydrogen sulfide, ammonia and chlorides (when present) will combine to form ammonium bisulfide and ammonium chloride. Where this occurs within the exchanger system depends on concentration and temperature. If deposits occur, under-deposit corrosion may take place.
In order to minimize this corrosion, refiners typically employ water wash strategies and system monitoring. With a high degree of contaminants, filming corrosion inhibitors can reduce corrosion to the process surface, and salt dispersant chemistry can minimize the potential for deposition in the system. The combination can help control corrosion in reactor effluent exchangers.
Programs, Products, Equipment and Services
Explore Our React Corrosion Control Offerings
Get In Touch with Us
Give Us a Call
With unparalleled expertise and cutting-edge technology, we partner with customers to deliver world-class results and optimized operations. Contact us to learn how we can help you.
Nalco Water
1601 W. Diehl Road
Naperville, Il 60563
Thank you for your interest in our chemical processing industry products and services.
Nalco Water Customer Service: +1-800-288-0879
Contact Us
Related Hydroprocessing Solutions

Heat Exchanger Modeling
Heat exchanger modeling is used to track changes in heat exchanger fouling, look at associated economics and do root cau...

Heat Exchanger Modeling
Heat exchanger modeling is used to track changes in heat exchanger fouling, look at associated economics and do root cau...

Stabilizer Tower Fouling
Prevent inefficient distillation and under-deposit corrosion caused by ammonium chloride salting that fouls the stabiliz...

Stabilizer Tower Corrosion Control
Stabilizer tower overhead corrosion can be minimized by the application of unique filming corrosion inhibitors that are ...

Stabilizer Tower Fouling
Prevent inefficient distillation and under-deposit corrosion caused by ammonium chloride salting that fouls the stabiliz...

Stabilizer Tower Corrosion Control
Stabilizer tower overhead corrosion can be minimized by the application of unique filming corrosion inhibitors that are ...

Refinery Equipment Cleaning
Nalco Water cleaning and degassing programs minimize time needed during turnarounds to clean and degas systems for entry...

Reactor Bed Fouling
Extend unit run length and increase on-stream time with our reactor bed pressure reduction technology.

Reactor Bed Fouling
Extend unit run length and increase on-stream time with our reactor bed pressure reduction technology.
